{"product_id":"ge-fanuc-is200acleh1acb-application-control-layer-module","title":"GE Fanuc IS200ACLEH1ACB Application Control Layer Module","description":"\u003ch3\u003e\u003cstrong\u003eGE IS200ACLEH1A – Application Control Layer Module\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePart of the EX2100 Excitation Control System | Functional Revision A | Conformal Coating\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Information:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Abbreviation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eACLE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIS200ACLEH1A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE (General Electric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEX2100 Excitation Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Description:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApplication Control Layer Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Functional Revision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA (Functional Revision)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstruction Manual:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGEI-100584A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePCB Coating Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal Coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware Configuration:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGE Turbine Control Systems Solutions eTCSS CD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eToolbox and EX2100 Excitation Control Software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200ACLEH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicroprocessor-based Application Control Layer Module (ACLE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor use in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEX2100 Excitation System\u003c\/strong\u003e, a specialized subsystem of the broader\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VI Turbine Control System Series\u003c\/strong\u003e. This module is designed to manage high-level control tasks and execute multiple operations simultaneously through Ethernet-based communication networks.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eversion (ACLEH1A) is the base-level module and a predecessor to the upgraded IS215 version. It serves as a master controller in excitation applications, relying on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Control System Toolbox\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor configuration and software management.\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Highlights:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaster Controller Functionality:\u003c\/strong\u003e\u003cbr\u003eExecutes multiple tasks in parallel using Ethernet communication within turbine excitation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware \u0026amp; Configuration Requirements:\u003c\/strong\u003e\u003cbr\u003eCompatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Control System Toolbox\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeTCSS CD\u003c\/strong\u003e, designed specifically for the EX2100 Excitation Control System.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cbr\u003ePart of GE’s EX2100 Excitation System, which belongs to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark VI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTurbine Control architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtective Coating:\u003c\/strong\u003e\u003cbr\u003eFeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating\u003c\/strong\u003e—a thin chemical layer applied across the PCB surface for protection against moisture, dust, and other environmental contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Why is the IS200ACLEH1A's 'A' revision considered a functional revision?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 'A' revision is termed a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efunctional revision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebecause it modifies the device's core performance capabilities and system behavior, rather than making changes related to appearance or environmental durability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the purpose of the conformal coating on the PCB?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a protective chemical layer applied to the circuit board. It safeguards the module from environmental stress such as moisture, dust, and corrosion, enhancing operational reliability.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":50432821854504,"sku":"IS200ACLEH1ACB","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/IS200ACLEH1ACB1.jpg?v=1753231938","url":"https:\/\/www.powerdcs.com\/products\/ge-fanuc-is200acleh1acb-application-control-layer-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}