{"product_id":"ge-fanuc-l30-n00-vuh-f8l-h6l-lxx-nxx-r7c-plc-modul","title":"GE Fanuc L30-N00-VUH-F8L-H6L-LXX-NXX-R7C PLC Module","description":"\u003ch2\u003e\u003cstrong\u003eGE L30-N00-VFH-F8L-H6L-LXX-NXX-R7C – Line Current Differential Protection Relay\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE L30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecost-effective, high-performance line current differential protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esub-transmission and medium voltage lines and cables\u003c\/strong\u003e. Engineered for secure and reliable operation under the most demanding power system conditions, the L30 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efast and dependable three-pole tripping\u003c\/strong\u003e, enhanced interoperability, and advanced communication features for modern grid applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct No.:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eL30-N00-VFH-F8L-H6L-LXX-NXX-R7C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn Stock\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtection Relay Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePayment Methods:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eT\/T, Western Union\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1000g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Ports:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShanghai \/ Yiwu \/ Shenzhen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e12 Months\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features \u0026amp; Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecure, High-Speed Fault Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProven current differential protection for fast and reliable tripping in fault conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Communication Support\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports inter-relay communication via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edirect fiber\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS422\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG.703\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC37.94\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSynchrophasor measurement over Ethernet as per\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE C37.118\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive IEC 61850 Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCertified for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 Ed. 1 and Ed. 2\u003c\/strong\u003e, with full settings via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCL files\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850-9-2LE\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61869\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850-9-2 Hardfiber\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRoutable GOOSE (R-GOOSE)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnables wide-area protection and control through substation-external messaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Sensitivity \u0026amp; Accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edynamic charging current compensation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003easymmetry compensation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor superior sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdaptive restraint algorithms protect against CT saturation and measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Phasor Measurement Unit (PMU)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompliant with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEEE C37.118 (2011)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850-90-5\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCybersecurity\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCyberSentry™\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esecurity suite to meet modern cybersecurity standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible I\/O Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModular design with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density I\/O\u003c\/strong\u003e, customizable programmable logic, and scalable architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntuitive Full-Color Display\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time bay mimic visualization, annunciation, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephasor graphics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor on-site monitoring and control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSub-transmission line protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMedium voltage cable protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide-area monitoring and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial and utility substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":50440217493800,"sku":"L30-N00-VUH-F8L-H6L-LXX-NXX-R7C","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/L30-N00-VFH-F8L-H6L-LXX-NXX1_b5b06362-6af1-443d-ab5f-ac71994af6f4.jpg?v=1753415354","url":"https:\/\/www.powerdcs.com\/products\/ge-fanuc-l30-n00-vuh-f8l-h6l-lxx-nxx-r7c-plc-modul","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}