{"product_id":"ge-fanuc-wesdacd20k-module-brand-new-in-stock","title":"GE FANUC WESDACD20K Module Brand new in Stock","description":"\u003ch2\u003e\u003cstrong\u003eD20 Control Module Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD20 Control Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a two-part, detachable unit consisting of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWESDAC D20 K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Top Module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWESTERM D20 K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Bottom Module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis modular design enables flexible operation, easy maintenance, and simplified field installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eModule Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWESDAC D20 K (Top Module):\u003c\/strong\u003e\u003cbr\u003eResponsible for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata processing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the D20 main processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWESTERM D20 K (Bottom Module):\u003c\/strong\u003e\u003cbr\u003eActs as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etermination board\u003c\/strong\u003e, handling all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield wiring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical connections\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the WESDAC D20 K.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Connections via WESTERM D20 K\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eD.20 Network Ports\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e9600 Baud RS232 Maintenance Port\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Address Configuration (Jumper Block)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay Outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExternal DC Supply (for control output voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eD20K Control Output Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 control output points\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports various\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware\/software configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto meet system requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esecure operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof control outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExecutes control actions (initiation, timing, reset, and validation) as commanded by the D20 main processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eAdditional Functional Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLocal\/Remote Switch:\u003c\/strong\u003e\u003cbr\u003eA manual switch to disable relay coil power during maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSends an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoff-line status\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the D20 processor, which is forwarded to the host as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epseudo status\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Output Fusing:\u003c\/strong\u003e\u003cbr\u003eIntegrated fusing for additional protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTwo DB9 Connectors:\u003c\/strong\u003e\u003cbr\u003eAllow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edaisy-chaining\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the D.20 Link (communication between D20 CPU and WESDAC D20 K)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlso provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the WESDAC D20 K through the same cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOne DB9 Connector:\u003c\/strong\u003e\u003cbr\u003eFor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWESMAINT D20 maintenance port\u003c\/strong\u003e, accessible via a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVT100 terminal emulator\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eAddress Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper Block Location:\u003c\/strong\u003e\u003cbr\u003eSituated on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWESTERM D20 K\u003c\/strong\u003e, used to assign the WESDAC D20 K’s address on the D.20 link\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eDesign \u0026amp; Maintenance Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWESTERM D20 K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtains only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epassive components\u003c\/strong\u003e, while all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eactive components\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereside in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWESDAC D20 K\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThis design allows for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeasy replacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the WESDAC D20 K without disrupting field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for reducing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaintenance time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eminimizing system downtime\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":50435864363304,"sku":"WESDACD20K","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/WESDACD20K1.jpg?v=1753319087","url":"https:\/\/www.powerdcs.com\/products\/ge-fanuc-wesdacd20k-module-brand-new-in-stock","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}