{"product_id":"hima-22100-output-module-for-planar4-safety-systems","title":"HIMA 22100 Output Module for Planar4 Safety Systems","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA 22100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-fold output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for demanding safety-critical applications. As part of the trusted\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlanar4 system family\u003c\/strong\u003e, it ensures outstanding fault tolerance, reliability, and system integrity in industrial environments.\u003c\/p\u003e\n\u003cp\u003eDesigned and manufactured by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA Paul Hildebrandt\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e22100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeets the highest international safety standards, making it ideal for systems that require continuous operational safety.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 4 \/ CAT.4 certified\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor maximum safety integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour independent output channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensure redundancy and reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperates at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 W power rating\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and lightweight design:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.5 × 12.7 × 20.3 cm\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.35 lbs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA Planar4 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt with precision for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIPPS\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmergency Stop\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eShutdown Systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" style=\"width: 100%; height: 293.907px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 44.3639%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e\u003cstrong\u003e22100\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e4-Fold Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003ePlanar4 System Family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eSafety Integrity Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003eSIL 4 \/ CAT.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e4 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e2.5 × 12.7 × 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e0.35kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eProduct Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eManufacturer Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e98 4022100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eCertificates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003eCE, FCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 52.7789%; height: 19.5938px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 44.3639%; height: 19.5938px;\"\u003e1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA 22100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to enhance operational safety and reliability across critical control systems, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Integrity Pressure Protection Systems (HIPPS)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Stop Systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor hazardous industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Shutdown Systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure safe process termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePLC and Machine Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin safety automation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA 22100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers unmatched stability and performance with its SIL4-certified architecture. Its compact dimensions and modular design allow fast installation on standard DIN rails, while the four output channels provide continuous process protection under high-risk conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the HIMA 22100 an original and new module?\u003c\/strong\u003e\u003cbr\u003eYes, all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA 22100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodules are\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrand new and 100% original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom HIMA factories.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How soon can you ship the HIMA 22100 after payment?\u003c\/strong\u003e\u003cbr\u003eWe ship\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewithin 3 days to 2 weeks\u003c\/strong\u003e, depending on order quantity and logistics. Common carriers include\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDHL, FedEx, and UPS\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens if the product has a quality issue?\u003c\/strong\u003e\u003cbr\u003eWe offer a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30-day return policy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor any verified quality problem.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Which systems are compatible with HIMA 22100?\u003c\/strong\u003e\u003cbr\u003eThe module integrates seamlessly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIMA Planar4 systems\u003c\/strong\u003e, widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess control and safety instrumented systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What is the operating voltage and power requirement?\u003c\/strong\u003e\u003cbr\u003eIt operates at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower consumption.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":50835054756136,"sku":"22100","price":212.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/221001.jpg?v=1760596270","url":"https:\/\/www.powerdcs.com\/products\/hima-22100-output-module-for-planar4-safety-systems","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}