{"product_id":"honeywell-51309152-175-mc-paox03-analog-output-module","title":"Honeywell 51309152-175 MC-PAOX03 Analog Output Module","description":"\u003cp\u003eConfigured for high-accuracy 8-channel current loop drive in Honeywell High-Performance Process Manager (HPM) systems, the \u003cstrong\u003eHoneywell 513092152-175\u003c\/strong\u003e (\u003cstrong\u003eMC-PAOX03\u003c\/strong\u003e Analog Output Modules) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51309152-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eMC-PAOX03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0.1 mA to 21.4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Current\u003c\/td\u003e\n\u003ctd\u003e26 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.35% at 25 deg C (including linearity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Resistive Load\u003c\/td\u003e\n\u003ctd\u003e750 ohms at 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e100 mV peak-to-peak across 250 ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Withstand\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C37.90.1-1978\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg (shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard High-Performance Process Manager IOP module slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eCabinet backplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Galvanic Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-PAOX03 8-channel analog output processor supports redundant configuration via field-replaceable relay switch modules mounted on the Field Termination Assembly (FTA). The outputs maintain channel-to-channel isolation and low output ripple (100 mV peak-to-peak across a 250 ohm load) across the entire 0.1 mA to 21.4 mA current range. Designed with conformal coating on all internal printed circuit board assemblies, the unit protects 4-20 mA HART loop protocol driving circuits from corrosive environmental gases and humidity exposure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is physical redundancy managed on the MC-PAOX03 output circuit?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy is achieved through electrical isolation via a field-replaceable relay switch module situated on the associated FTA, preventing primary channel faults from corrupting the secondary backup signal loop.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum load resistance supported by each analog output channel?\u003c\/p\u003e\n\u003cp\u003eA: Each channel drives resistive loads up to 750 ohms at a full-scale current output of 22 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConformal Coating Inspection:\u003c\/strong\u003e Verify that the conformal coating layer remains intact and unmarred across all PCB traces prior to card cage insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Wire Grounding:\u003c\/strong\u003e Terminate individual signal cable shields to the system signal ground bar at the FTA end only to eliminate ground loop currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Impedance Verification:\u003c\/strong\u003e Ensure total loop resistance, including field wiring and actuator input impedance, does not exceed 750 ohms per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion:\u003c\/strong\u003e Engage card edge guides smoothly and tighten front panel retaining screws to ensure proper backplane power and signal grounding.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52385543586088,"sku":"MC-PAOX03 51309512-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MC-PAOX0351309512-175.jpg?v=1789459638","url":"https:\/\/www.powerdcs.com\/products\/honeywell-51309152-175-mc-paox03-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}