{"product_id":"honeywell-51403988-150-high-performance-process-manager-comm-controller","title":"Honeywell 51403988-150 High Performance Process Manager Comm Controller","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51403988-150\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eHPMM Comm Controller\u003c\/strong\u003e High Performance Process Manager Comm Controller, operates as a dedicated hardware component for high-speed node communication management within Honeywell TDC 3000 and Experion PKS networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51403988-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.39 kg (Net weight) \/ 1.5 kg (Shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell HPMM Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via backplane DC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Controller Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh Performance Process Manager (HPMM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Protocol\u003c\/td\u003e\n\u003ctd\u003eDual-redundant I\/O link and UCN communication bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Communication \u0026amp; Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 51403988-150 communication controller executes deterministic packet transfer between the High Performance Process Manager (HPMM) backplane and remote I\/O sub-networks. Designed to interface with 4-20 mA HART loop protocol databases and DCS fieldbus networks, the module provides embedded line drivers with channel-to-channel isolation. This isolation barrier prevents common-mode ground transients and field line noise from corrupting high-speed serial communications across Universal Control Network (UCN) interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What function does the 51403988-150 serve within an HPMM cabinet?\u003c\/p\u003e\n\u003cp\u003eA: It acts as the primary communication processor board, handling serial protocol management, token bus synchronization, and data traffic between the controller processor and field I\/O racks.\u003c\/p\u003e\n\u003cp\u003eQ: How does channel-to-channel isolation benefit network stability on the 51403988-150?\u003c\/p\u003e\n\u003cp\u003eA: Channel-to-channel isolation blocks transient voltage spikes and ground loops, protecting the internal communication logic from electrical disturbances on extended field network cables.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping supported for the 51403988-150 module during operation?\u003c\/p\u003e\n\u003cp\u003eA: Removal or insertion must strictly follow Honeywell HPMM redundant rack procedures to prevent disruption to active UCN bus communication loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect backplane power or verify redundant controller status before extracting or seating the 51403988-150 card.\u003c\/li\u003e\n\u003cli\u003eEnsure communication cables are properly shielded with 360-degree drain wire termination connected directly to the cabinet earthing bar.\u003c\/li\u003e\n\u003cli\u003eSlide the circuit card evenly along the chassis card guides until the backplane multi-pin connectors click firmly into place.\u003c\/li\u003e\n\u003cli\u003eRoute high-speed communication lines separately from high-voltage AC lines to minimize electromagnetic interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52393151398184,"sku":"MC-HPMR01 51403988-150","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MC-HPMR0151403988-1501.jpg?v=1789551035","url":"https:\/\/www.powerdcs.com\/products\/honeywell-51403988-150-high-performance-process-manager-comm-controller","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}