Honeywell 8C-PDOLA1 Series 8 Digital Output Module
Specifications
Manufacturer: Honeywell
Product No.: 8C-PDOLA1
Condition: 10 Items in Stock
Product Type: Digital Output Cards
Product Origin: USA
Payment:T/T, Western Union
Weight: 450g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
The Honeywell 8C-PDOLA1, also cataloged as the 8C-PDOLA1 Digital Output Module, operates as a dedicated hardware component for 24 VDC sourcing discrete output control execution within Honeywell Experion PKS Series 8 platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8C-PDOLA1 |
| Brand | Honeywell |
| Origin | USA |
| Operating Temp | -20 to +60 deg C |
| Power Consumption | 24 VDC sourcing backplane power |
| Module Type | Digital Output Module |
| Output Channels | 32 channels |
| Output Rating | 100 mA max per channel at 24 VDC |
| Coating | Conformal coated PCB |
Channel-to-Channel Isolation & Output Loop Performance
The 8C-PDOLA1 controls 32 discrete outputs via 24 VDC sourcing current switches designed to actuate solenoids, relays, and field interlocks. Incorporating channel-to-channel isolation and integrated line diagnostic circuits, the module detects open-circuit and short-circuit wiring conditions across field loops. The galvanically isolated output stages prevent inductive field switching transients from coupling into adjacent 4-20 mA HART loop protocol lines and system I/O buses.
Frequently Asked Questions
Q: Does the 8C-PDOLA1 support hot-swapping during active system operation?
A: Yes, the module can be inserted or removed under power without interrupting adjacent Series 8 I/O module communications or backplane bus integrity.
Q: What is the maximum load current capability per channel on the 8C-PDOLA1?
A: Each individual output channel supports up to 100 mA sourcing current at 24 VDC.
Field Installation Guidelines
- Align the module housing with the designated slot guide rails on the Series 8 I/O terminal assembly base before seating backplane connectors.
- Route field wiring bundles separately from high-voltage AC lines to minimize electromagnetic coupling into discrete output circuits.
- Ensure the module mechanical latching mechanism is fully engaged to guarantee chassis grounding and prevent loose connection faults.
- Verify cabinet temperature remains within the specified -20 to +60 deg C operating range to maintain normal output switching parameters.
How to Get a Quote
Order Tracking
Shipping Carriers
Refund Policy and Conditions
Warranty Conditions
Related Products