{"product_id":"honeywell-8c-taida1-51307131-175-series-8-analog-input-module","title":"Honeywell 8C-TAIDA1 51307131-175 Series 8 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAIDA1 51307131-175\u003c\/strong\u003e serves as the primary \u003cstrong\u003e8C-TAIDA1\u003c\/strong\u003e Analog Input Module utilized to execute analog signal processing and field instrument data acquisition across Experion PKS Series 8 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIDA1 51307131-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 120 mm x 228.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eUnspecified (24 VDC system power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307131-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V, RTD, Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 8 chassis \/ IOTA base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TAIDA1 51307131-175 conditions incoming process variables from 4-20 mA current loops, 0-10 V voltage ranges, RTDs, and thermocouples across 16 single-ended channels. Internal analog-to-digital converting networks integrate channel-to-channel isolation and galvanic barriers to block ground loop propagation, common-mode voltage spikes, and cross-talk noise between independent process loops. When integrated into compatible Series 8 IOTA carrier assemblies, the circuitry passes 4-20 mA HART loop protocol digital communication directly to the C300 controller backplane without disturbing primary process variable conversion.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 8C-TAIDA1 51307131-175 process different input signal types across its 16 channels?\u003c\/p\u003e\n\u003cp\u003eA: Signal type selection (4-20 mA, 0-10 V, RTD, or Thermocouple) is assigned per channel via software parameterization in the Experion PKS environment.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 8C-TAIDA1 51307131-175 support hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, removal and insertion under power (RIUP) is supported when mounted on compatible Series 8 IOTA bases without disturbing adjacent operational I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting mechanism is required for installation?\u003c\/p\u003e\n\u003cp\u003eA: The module mounts directly onto a standard Series 8 chassis \/ IOTA base carrier interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA Slot Alignment\u003c\/strong\u003e: Align the rear edge connector with the designated Series 8 IOTA position and push firmly until the side locking latches snap into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Terminate field instrument cable shield drain wires to a dedicated earth ground bar within the cabinet to prevent electrical noise from degrading 4-20 mA or millivolt signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRaceway Wiring\u003c\/strong\u003e: Separate low-level analog input wiring from high-voltage AC distribution circuits and variable frequency drive (VFD) output cables.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52312977539368,"sku":"8C-TAIDA1 51307131-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/8C-TAIDA1.png?v=1788256348","url":"https:\/\/www.powerdcs.com\/products\/honeywell-8c-taida1-51307131-175-series-8-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}