Honeywell 8C-TDIL61 51306967-175 I/O Module
Specifications
Manufacturer: Honeywell
Product No.: 8C-TDIL61 51306967-175
Condition: 10 Items in Stock
Product Type: I/O Modules
Product Origin: USA
Payment:T/T, Western Union
Weight: 500g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
The Honeywell 8C-TDIL61 51306967-175, also cataloged as the 8C-TDIL61 I/O Module, operates as a dedicated hardware component for field signal acquisition and processing within Honeywell Experion PKS Series 8 C300 controller networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8C-TDIL61 51306967-175 |
| Brand | Honeywell |
| Origin | United States |
| Weight | 0.5 kg |
| Dimensions | 10.8 cm x 8.7 cm x 7.8 cm |
| Operating Temp | -40 to 70 deg C |
| Power Consumption | 2.5 W nominal |
| Input Type | High Level Analog / Digital Input / HART Interface |
| Channel Count | 16 Channels |
| Signal Range | 4-20 mA DC / 24 VDC Discrete Input |
HART Communication and Galvanic Channel Isolation
The Honeywell 8C-TDIL61 51306967-175 interface leverages 4-20 mA HART loop protocol pass-through technology to fetch primary, secondary, and tertiary process control variables directly into the Experion C300 control matrix. Integrated channel-to-channel isolation prevents ground loop currents from contaminating high-level analog and discrete input signals. This physical channel isolation protects sensitive backplane electronics from field-side voltage transients and external common-mode noise.
Frequently Asked Questions
Q: Does the 8C-TDIL61 module support online hot-swapping during active system operation?
A: Yes, the module supports Removal and Insertion Under Power (RIUP) when installed on a compatible Series 8 I/O carrier, provided backplane power distribution tolerances are strictly maintained.
Q: How is signal wiring terminated on the 8C-TDIL61 assembly?
A: Wiring terminates directly via standard screw terminals or compression block assemblies attached to the dedicated Series 8 I/O termination assembly (TA).
Field Installation Guidelines
- Ensure the C300 I/O carrier frame is fully grounded to the local plant instrument earth before snapping the module onto the DIN rail carrier assembly.
- Route 4-20 mA HART field instrument cables in dedicated shielded twisted-pair conduits, keeping signal lines isolated from high-voltage AC power wiring.
- Terminate cable shields at the single designated cabinet ground point to prevent ground loops across differential input channels.
- Maintain a minimum engagement of 5 full threads on all NPT conduit connections entering the field enclosure to maintain enclosure ingress ratings.