Honeywell 900B08-0001 Analog Output Module
Specifications
Manufacturer: Honeywell
Product No.: 900B08-0001
Condition: 10 Items in Stock
Product Type: Analog Output Modules
Payment:T/T, Western Union
Weight: 260g
Shipping port: Xiamen
Warranty: 12 months
Product details
Description
Configured for 8-channel analog current output generation within Modular Controller Series platforms, the Honeywell 900B08-0001 (900B08-0001 Analog Output Module) provides direct physical/electrical execution of 4-20 mA control loops.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 900B08-0001 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.26 kg (0.57 lbs) |
| Dimensions | Standard Modular Controller Series module footprint |
| Operating Temp | 0 to +60 deg C |
| Power Consumption | Backplane and loop-supplied DC power |
| Product Type | Analog Output Module |
| Channel Capacity | 8 Independent Channels |
| Signal Output | 4-20 mA Current Output |
| Suggested Replacement | 900B08-0202 |
| System Compatibility | Honeywell Modular Controller Series / ControlEdge HC900 |
4-20 mA HART Loop Protocol and Channel-to-Channel Isolation
The module incorporates channel-to-channel galvanic isolation across all 8 independent output paths to prevent common-mode noise and ground potential loops from distorting field control signals. Internal digital-to-analog converter channels condition loop currents while preserving 4-20 mA HART protocol communication capability for bi-directional diagnostics with final control elements. Isolation barriers protect internal backplane electronics from transient voltage spikes originating in field actuator wiring.
Frequently Asked Questions
Q: Can the 900B08-0001 module be replaced directly by model 900B08-0202?
A: Yes, model 900B08-0202 is the designated manufacturer-suggested hardware replacement for legacy 900B08-0001 installations within the controller rack.
Q: Are the 8 analog output channels galvanically isolated from each other?
A: Yes, each output channel features independent isolation to block common-mode interference and prevent inter-channel crosstalk.
Field Installation Guidelines
- Verify that controller rack power and loop power feeds are de-energized before mounting or servicing the module.
- Align module card edges with the designated rack slot guide rails and push firmly until backplane connectors engage completely.
- Terminate 4-20 mA field loop wiring to the corresponding terminal blocks, verifying correct positive and negative polarity for all 8 channels.
- Fasten module retaining screws securely to maintain continuous chassis ground bonding and physical stability under plant vibration.
How to Get a Quote
Order Tracking
Shipping Carriers
Refund Policy and Conditions
Warranty Conditions
Related Products
- Choosing a selection results in a full page refresh.