{"product_id":"honeywell-cc-hcn911-51307206-175-experion-pks-c300-baseplate","title":"Honeywell CC-HCN911 51307206-175 Experion PKS C300 Baseplate","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-HCN911 51307206-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-HCN911\u003c\/strong\u003e (part number \u003cstrong\u003e51307206-175\u003c\/strong\u003e) C300 Baseplate, operates as a dedicated hardware component for physical mounting, power distribution, and backplane bus routing within Honeywell Experion PKS C300 controller systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-HCN911 51307206-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 double-wide baseplate footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C (-40 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive backplane routing (bus powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51307206-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eC300 Controller \u0026amp; I\/O backplane interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard cabinet DIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Galvanic Signal Decoupling\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-HCN911 51307206-175 baseplate acts as the structural foundation for hosting C300 controllers and associated network interface cards. It incorporates integrated backplane traces that facilitate galvanic isolation between processing units and external communication channels. When interfacing with remote field channels handling 4-20 mA HART loop protocol signals or FOUNDATION Fieldbus links, the underlying baseplate bus maintains low-impedance grounding paths and channel-to-channel crosstalk suppression to preserve data integrity across DCS nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing the CC-HCN911 baseplate require powering down the C300 controller node?\u003c\/p\u003e\n\u003cp\u003eA: Yes, because the baseplate provides the underlying physical backplane connections, replacing the CC-HCN911 requires de-energizing the power supply rails and removing mounted modules prior to baseplate uninstallation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the CC-HCN911 support system redundancy within the Experion PKS network?\u003c\/p\u003e\n\u003cp\u003eA: The dual-slot physical layout of the CC-HCN911 baseplate provides dedicated backplane interconnection traces that support primary and secondary C300 controller modules operating in a redundant lockstep configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all system power feeds to the mounting enclosure are completely de-energized before installing or replacing the baseplate assembly.\u003c\/li\u003e\n\u003cli\u003eSecure the CC-HCN911 baseplate onto the cabinet panel or DIN rail, ensuring all mechanical mounting screws are torqued down to provide adequate chassis frame grounding.\u003c\/li\u003e\n\u003cli\u003eVerify that adjacent baseplate extension cables are locked firmly into their respective backplane connectors to maintain uninterrupted bus communications.\u003c\/li\u003e\n\u003cli\u003eKeep low-voltage communication and I\/O bus cables routed in dedicated raceways separated from AC power lines by a minimum distance of 200 mm.\u003c\/li\u003e\n\u003cli\u003eConnect the baseplate ground lug directly to the main cabinet protective earth (PE) bus using a short, low-impedance grounding strap.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357096767784,"sku":"CC-HCN911 51307206-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-HCN911.jpg?v=1788937883","url":"https:\/\/www.powerdcs.com\/products\/honeywell-cc-hcn911-51307206-175-experion-pks-c300-baseplate","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}