{"product_id":"honeywell-cc-taim01-51305959-175-analog-input-module","title":"Honeywell CC-TAIM01 51305959-175 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TAIM01 51305959-175\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TAIM01\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for millivolt signal acquisition and RTD resistance processing within Experion PKS Series C platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAIM01 51305959-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC IOTA bus supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLow Level Analog Input Multiplexer Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51305959-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Support\u003c\/td\u003e\n\u003ctd\u003eThermocouples (TC) and Resistance Temperature Detectors (RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eG3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eConfigurable upscale or downscale sensor burnout detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CC-TAIM01 module utilizes dedicated Cold Junction Compensation (CJC) algorithms and reference junction hardware to maintain measurement accuracy across temperature-critical thermocouple channels. Integrated differential multiplexing circuits combined with high-order analog filtering isolate incoming millivolt-level signals from high-frequency electromagnetic noise. Channel-to-channel isolation barriers prevent ground loop currents from skewing low-amplitude signal paths, delivering stable temperature readings into the Experion PKS Control Execution Environment (CEE).\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the CC-TAIM01 handle a broken or disconnected thermocouple sensor?\u003c\/p\u003e\n\u003cp\u003eA: Each channel features configurable upscale or downscale burnout detection that automatically flags open-circuit conditions to the controller, preventing stale data from affecting control logic.\u003c\/p\u003e\n\u003cp\u003eQ: Can different thermocouple types be wired to channels on the same CC-TAIM01 module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, channels are individually software-configurable for distinct thermocouple types or RTD curves, provided appropriate compensation wiring is landed at the terminal assembly.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental protections are built into the -175 hardware revision?\u003c\/p\u003e\n\u003cp\u003eA: The -175 revision includes standard G3 conformal coating, protecting internal circuitry against airborne corrosives, moisture, and chemical vapors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the CC-TAIM01 vertically onto its designated Series C IOTA slot until the mechanical retention clips fully lock.\u003c\/li\u003e\n\u003cli\u003eTerminate thermocouple extension wires or RTD leads using shielded, twisted-pair cabling directly to the IOTA screw terminal block.\u003c\/li\u003e\n\u003cli\u003eConnect the cable shield drain wire to the cabinet single-point ground bar to minimize common-mode voltage interference.\u003c\/li\u003e\n\u003cli\u003eVerify that Cold Junction Compensation sensors on the terminal assembly are installed and isolated from direct cabinet thermal discharge.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52342874931496,"sku":"CC-TAIM01 51305959-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TAIM0151305959-175.png?v=1788767956","url":"https:\/\/www.powerdcs.com\/products\/honeywell-cc-taim01-51305959-175-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}