{"product_id":"honeywell-experion-c300-analog-input-module-cc-paix01","title":"Honeywell Experion C300 Analog Input Module | CC-PAIX01","description":"\u003cp\u003eConfigured for multi-channel process variable conversion and signal conditioning in Honeywell Experion PKS Series C platforms, the \u003cstrong\u003eHoneywell CC-PAIX01 51405038-275\u003c\/strong\u003e (\u003cstrong\u003eCC-PAIX01\u003c\/strong\u003e High-Level Analog Input Module) provides direct physical\/electrical execution. It converts incoming field signals into digitized process variables across 16 analog input channels for real-time controller logic execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIX01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51405038-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.299 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e307.34 mm x 124.46 mm x 63.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC IOTA backplane distribution lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 High-Level Analog Input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Signals\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, Temperature, Pressure transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion Series C \/ C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIX01 analog input module incorporates dedicated digital conversion circuitry to process standard 4-20 mA current and high-level voltage signals across its 16 channels. Integrated channel-to-channel isolation decouples field-side loops from backplane bus electronics, suppressing common-mode voltage spikes and eliminating potential ground loops between field instrument drops. The hardware architecture supports HART pass-through communications, allowing transparent digital variable acquisition, transmitter diagnostics, and remote calibration updates directly from the Experion DCS host without disrupting analog current loop continuity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CC-PAIX01 module be hot-swapped during active DCS operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CC-PAIX01 supports live insertion and removal on an energized Series C IOTA board, allowing online module replacement without interrupting adjacent channel processing or system backplane communication.\u003c\/p\u003e\n\u003cp\u003eQ: How does the internal isolation circuitry protect system backplane components?\u003c\/p\u003e\n\u003cp\u003eA: Channel-to-channel isolation barriers decouple field-side wiring loops from internal processing logic, attenuating high-voltage surges and ground potential offsets before they reach the controller bus.\u003c\/p\u003e\n\u003cp\u003eQ: What power source supplies the primary operational current for the CC-PAIX01?\u003c\/p\u003e\n\u003cp\u003eA: The module draws its logic power directly from the 24 VDC redundant backplane distribution rails located on the Series C IOTA carrier assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane connectors and plastic alignment guides on the Series C IOTA slot to ensure freedom from debris or physical damage prior to insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the CC-PAIX01 card edge with the vertical guide tracks of the assigned slot on the I\/O Termination Assembly.\u003c\/li\u003e\n\u003cli\u003eSeat the module firmly into the backplane connector until the top and bottom mechanical locking latches fully engage.\u003c\/li\u003e\n\u003cli\u003eRoute field transmitter wiring through designated wire channels and terminate on the IOTA screw blocks, ensuring cable shield drain wires are tied to the earth ground bar at a single point.\u003c\/li\u003e\n\u003cli\u003eVerify power supply bus integrity and IOTA terminal voltages prior to commissioning the 16 analog input loops within the controller database.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52346544685352,"sku":"CC-PAIX01 51405038-275","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-PAIX0151405038-275_Cocoai.png?v=1788852737","url":"https:\/\/www.powerdcs.com\/products\/honeywell-experion-c300-analog-input-module-cc-paix01","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}