{"product_id":"honeywell-experion-pks-c300-hart-analog-input-module-cc-paih02","title":"Honeywell Experion PKS C300 HART Analog Input Module | CC-PAIH02","description":"\u003cp\u003eConfigured for high-density current and voltage signal processing in Experion PKS C300 systems, the \u003cstrong\u003eHoneywell CC-PAIH02\u003c\/strong\u003e (\u003cstrong\u003eCC-PAIH02\u003c\/strong\u003e HART Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C300 I\/O Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHART Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 V, 0-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eDifferential \/ Single-ended analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-PAIH02 processes up to 16 configurable differential or single-ended analog input channels across 4-20 mA, 1-5 V, and 0-5 V signal ranges. Operating over standard 4-20 mA HART loop protocol architectures, internal signal processing logic decouples field sensor circuits through dedicated channel-to-channel isolation networks. This electrical boundary prevents common-mode voltage spikes and ground loop currents from propagating into the core C300 controller backplane bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-PAIH02 support online insertion and removal under live backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports live hot-swapping on an active C300 carrier assembly without disrupting adjacent I\/O channel execution or requiring a controller restart.\u003c\/p\u003e\n\u003cp\u003eQ: How are differential and single-ended input modes selected on the module?\u003c\/p\u003e\n\u003cp\u003eA: Input configuration modes for 4-20 mA, 1-5 V, and 0-5 V ranges are software-defined within the Experion PKS Control Builder environment on a per-channel basis.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module pass HART diagnostic variables directly to asset management tools?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the onboard HART modem extracts primary, secondary, tertiary, and quaternary dynamic variables from the 4-20 mA analog loop for transmission over the backplane.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module chassis onto the designated slot of the C300 IOTA carrier board, pressing firmly until the retention clips lock into position.\u003c\/li\u003e\n\u003cli\u003eRoute 4-20 mA and low-voltage DC analog signal lines through dedicated wireways separated from AC power cables by at least 200 mm.\u003c\/li\u003e\n\u003cli\u003eTerminate shielded signal cable drain wires at a single common ground bus bar inside the cabinet to eliminate ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify loop power voltage levels and field device polarity prior to energizing input channels.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum vertical clearance of 100 mm above and below the module assembly to ensure unobstructed convective cooling airflow.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357518328104,"sku":"CC-PAIH02 51405038-175","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-PAIH0251405038-3751_939f9c45-0a48-48f1-815e-55a2e80e68f4.png?v=1788942490","url":"https:\/\/www.powerdcs.com\/products\/honeywell-experion-pks-c300-hart-analog-input-module-cc-paih02","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}