{"product_id":"honeywell-experion-pks-series-c-fieldbus-baseplate-cc-tfe021","title":"Honeywell Experion PKS Series-C Fieldbus Baseplate | CC-TFE021","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TFE021\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TFE021\u003c\/strong\u003e FOUNDATION Fieldbus Interface Module (FIM) Baseplate, operates as a dedicated hardware component for backplane power distribution and network routing within Honeywell Experion PKS Series-C platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TFE021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e304.8 mm x 127.0 mm x 50.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 VDC bus input execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51306713-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slots\u003c\/td\u003e\n\u003ctd\u003e2 slots for FIM4 \/ FIM8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eFOUNDATION Fieldbus H1 interface support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eG3 level harsh environment protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel mount or standard cabinet mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFOUNDATION Fieldbus \/ Profibus PA Connectivity and Power Routing\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TFE021 provides hardware backplane connections designed for FOUNDATION Fieldbus H1 and Profibus PA communications across Experion PKS Series-C controller networks. The baseplate routes redundant 24 VDC power rails directly to mounted Fieldbus Interface Modules while enforcing electrical isolation between high-speed system control buses and field segment connections. Integrated signal paths suppress transient coupling, preserving message timing and deterministic packet transmission across fieldbus segments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many Fieldbus Interface Modules can be mounted on the CC-TFE021 baseplate?\u003c\/p\u003e\n\u003cp\u003eA: The CC-TFE021 baseplate features dual module slots, allowing up to two Series-C FIM modules to be installed simultaneously in either standalone or redundant operational modes.\u003c\/p\u003e\n\u003cp\u003eQ: Does replacing a FIM module on the CC-TFE021 disrupt communications on adjacent slots?\u003c\/p\u003e\n\u003cp\u003eA: No, the baseplate supports online hot-swapping of individual FIM modules, permitting insertion or removal without removing system power or interrupting active control loops on the secondary slot.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power wiring connected directly to the baseplate board?\u003c\/p\u003e\n\u003cp\u003eA: Yes, redundant 24 VDC system power supplies and fault indication contacts wire directly to the terminal blocks integrated onto the baseplate assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSecure the baseplate to the cabinet backpanel using specified mounting screws, ensuring solid metal-to-metal contact at grounding points to establish chassis ground continuity.\u003c\/li\u003e\n\u003cli\u003eRoute primary and redundant 24 VDC power feeds to the dedicated power terminal blocks, verifying correct voltage levels and wiring polarity prior to energizing.\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet system cables and H1 fieldbus segment lines to their respective baseplate ports, securing shield ground connections to the cabinet single-point ground bus.\u003c\/li\u003e\n\u003cli\u003eAlign the guide pins of the FIM module with the target slot on the CC-TFE021 baseplate and press firmly until the locking lever fully latches into position.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum vertical clearance of 100 mm above and below the baseplate assembly within the panel enclosure to ensure proper convective cooling airflow.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52357421072680,"sku":"CC-TFE021","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/CC-TFB81151306751-175_Cocoai_eb30ae5e-d339-40ec-873a-479afbc7d158.png?v=1788941023","url":"https:\/\/www.powerdcs.com\/products\/honeywell-experion-pks-series-c-fieldbus-baseplate-cc-tfe021","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}