{"product_id":"honeywell-fc-qpp-0002-cc-v1-2-quad-processor-pack","title":"Honeywell FC-QPP-0002 CC v1.2 Quad Processor Pack","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-QPP-0002 CC v1.2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-QPP-0002\u003c\/strong\u003e Quad Processor, operates as a dedicated hardware component for high-integrity safety logic processing and execution within Honeywell Safety Manager and Fail Safe Control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-QPP-0002 CC v1.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e176 x 88.5 x 212 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 Vdc at 1.2 A max, 24 Vdc at 25 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eQuad Processor Pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Vdc (-15% to +30%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 V Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 Vdc (+\/- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e15-31 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e750 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eapprox. 8 mA at 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, TUV, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe main processing board provides physical galvanically isolated channels and internal power decoupling barriers to protect processing logic from voltage swings on field side lines. Signal routing paths filter line noise before field inputs reach internal bus registers, preventing common-mode noise propagation from disturbing connected 4-20 mA HART loop protocol interfaces. Isolated logic interfaces minimize ambient noise coupling across high-density I\/O subsystems and preserve high measurement fidelity across cold junction compensation (CJC) circuits within connected safety input modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power supply voltage limits for the FC-QPP-0002 CC v1.2?\u003c\/p\u003e\n\u003cp\u003eA: The module requires a regulated 5 Vdc supply (+\/- 5%) with a maximum current consumption of 1.2 A, alongside a 24 Vdc auxiliary line tolerance (-15% to +30%) pulling up to 25 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What short-circuit protections are built into the module output channels?\u003c\/p\u003e\n\u003cp\u003eA: Output paths feature continuous short-circuit protection and reverse-polarity safeguards, with driving capability up to 750 mA per channel.\u003c\/p\u003e\n\u003cp\u003eQ: What ambient temperature range is rated for module operation?\u003c\/p\u003e\n\u003cp\u003eA: Both internal module and external ambient envelope ratings support operating temperatures ranging from -5 to +70 deg C (10 to 95% non-condensing relative humidity).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSlide the processor pack squarely along chassis guide rails into its designated slot on the system backplane rack until rear connectors engage fully.\u003c\/li\u003e\n\u003cli\u003eSecure front retention screws to lock the assembly against backplane vibrations and ensure frame grounding continuity.\u003c\/li\u003e\n\u003cli\u003eVerify that 5 Vdc and 24 Vdc auxiliary rack power rails comply with tolerance limits prior to powering the rack enclosure.\u003c\/li\u003e\n\u003cli\u003eConnect all field communication and I\/O trunk cables using shielded twisted pair conductors terminated directly at the central earthing bar.\u003c\/li\u003e\n\u003cli\u003eMaintain clear convection air channels above and below the card cage module to prevent localized heat accumulation inside sealed cabinets.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52407127114024,"sku":"FC-QPP-0002 CC v1.2","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-QPP-0001.jpg?v=1789721485","url":"https:\/\/www.powerdcs.com\/products\/honeywell-fc-qpp-0002-cc-v1-2-quad-processor-pack","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}