{"product_id":"honeywell-fc-tsdi-16uni-safety-manager-system-module","title":"Honeywell FC-TSDI-16UNI Safety Manager System Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSDI-16UNI\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TSDI-16UNI\u003c\/strong\u003e Safety Manager System Module, operates as a dedicated hardware component for safe 16-channel discrete input processing within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSDI-16UNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eShipping Weight: 2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 70 x 60 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C (standard panel ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower consumption dependent on backplane and loop excitation draw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSafety Manager System Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 channels (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e50 VDC (IEC 61010-1 Overvoltage Category 3), 150 VDC (IEC 61010-1 Overvoltage Category 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail Mounting\u003c\/td\u003e\n\u003ctd\u003eDIN EN rails TS32 \/ TS35 x 7.5 (Used length: 91 mm \/ 3.58 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Specification\u003c\/td\u003e\n\u003ctd\u003e250 mAT slow-acting (5 x 20 mm \/ 0.2 x 0.79 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, max wire size 2.5 mm2 (AWG 14), strip length 7 mm, tightening torque 0.5 Nm (0.37 ft-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eDesigned for critical discrete input monitoring in safety-instrumented setups, the module provides isolated field contact interfacing across two distinct groups of 8 channels. Internal channel-to-channel isolation de-couples field-side potential differences, preventing ground loops and stray high-voltage transients from degrading signal accuracy or interfering with adjacent analog 4-20 mA HART instrument wiring runs within the same control enclosure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the electrical wiring limits for field connections on the FC-TSDI-16UNI screw terminal block?\u003c\/p\u003e\n\u003cp\u003eA: The integral screw terminals accept a maximum wire cross-section of 2.5 mm2 (AWG 14) with a strip length of 7 mm (0.28 in) and must be torqued to 0.5 Nm (0.37 ft-lb).\u003c\/p\u003e\n\u003cp\u003eQ: How is individual channel group protection handled on this module?\u003c\/p\u003e\n\u003cp\u003eA: Circuit protection is enforced using an internal 250 mAT slow-acting fuse measuring 5 x 20 mm, designed to interrupt overcurrent conditions on field lines before affecting central backplane logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all field power sources and rack backplane power before attaching or removing module wiring harnesses.\u003c\/li\u003e\n\u003cli\u003eMount the assembly securely onto standard TS32 or TS35 x 7.5 DIN rails, ensuring a minimum rail length engagement of 91 mm.\u003c\/li\u003e\n\u003cli\u003eStrip field conductors to exactly 7 mm and tighten screw terminals to 0.5 Nm to prevent loose contacts or thermal stress.\u003c\/li\u003e\n\u003cli\u003eMaintain separate raceways for discrete input field cables to avoid electromagnetic cross-talk from high-voltage AC cables.\u003c\/li\u003e\n\u003cli\u003eConnect all field cable shield drain wires to a central ground bus at a single point to maintain isolation integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52507092451624,"sku":"FC-TSDL-16UNI","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-TSDL-16UNI.png?v=1789895603","url":"https:\/\/www.powerdcs.com\/products\/honeywell-fc-tsdi-16uni-safety-manager-system-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}