{"product_id":"honeywell-fs-sicc-0001-l9-system-interconnection-cable","title":"Honeywell FS-SICC-0001\/L9 System Interconnection Cable","description":"\u003cp\u003eConfigured for multi-channel signal routing in Honeywell Safety Manager architectures, the \u003cstrong\u003eHoneywell FS-SICC-0001\/L9\u003c\/strong\u003e (\u003cstrong\u003eFS-SICC-0001\u003c\/strong\u003e System Interconnection Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-SICC-0001\/L9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eOuter Diameter: 9.93 mm (0.39 in), Cable Length: 9 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +85 deg C (-4 deg F to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive component (Voltage Rating: 300 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eSystem Interconnection Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Configuration\u003c\/td\u003e\n\u003ctd\u003e20 x AWG 22 (0.34 mm2), Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eDouble shielded for EMI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e120 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003ePre-terminated Honeywell-compatible connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Compliance\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant, UL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe double-shielded construction of the FS-SICC-0001\/L9 assembly preserves signal integrity across cabinet-to-cabinet interconnections. High channel-to-channel isolation is maintained along the 20-conductor bundle, suppressing crosstalk between adjacent telemetry pathways. This shielding architecture attenuates external electromagnetic interference (EMI), ensuring high-fidelity transmission of analog measurement signals and digital communication over 4-20 mA HART loop protocol connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical length does the L9 suffix denote for the FS-SICC-0001 series?\u003c\/p\u003e\n\u003cp\u003eA: The FS-SICC-0001\/L9 cable specifies a overall assembly length of 9 meters.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable assembly be hot-swapped during online maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Disconnecting the cable interrupts field signal pathways; redundant loop paths must be verified prior to removal to prevent unintended trip conditions.\u003c\/p\u003e\n\u003cp\u003eQ: How is EMI suppression achieved across the conductor core?\u003c\/p\u003e\n\u003cp\u003eA: The cable utilizes continuous double shielding combined with a 120 ohm nominal impedance profile along its full length.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eObserve minimum static and dynamic bend radius limits corresponding to the 9.93 mm outer diameter during cable tray routing.\u003c\/li\u003e\n\u003cli\u003eFasten pre-terminated connector locking mechanisms securely to FTA interface headers to prevent pin contact oxidation or vibration loosening.\u003c\/li\u003e\n\u003cli\u003eVerify shield continuity and ensure proper grounding at designated cabinet earth buses to avoid noise coupling and ground loops.\u003c\/li\u003e\n\u003cli\u003eAvoid running system interconnect cables in close parallel proximity to high-voltage AC power distribution conduits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52896478101800,"sku":"FS-SICC-0001\/L9","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FC-SICC-0001L101_Cocoai_07c6dbe0-b283-4a0f-a8ed-787e820b46b7.png?v=1790242967","url":"https:\/\/www.powerdcs.com\/products\/honeywell-fs-sicc-0001-l9-system-interconnection-cable","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}