{"product_id":"honeywell-fs-tsdo-0824-safe-digital-output-field-termination-assembly","title":"Honeywell FS-TSDO-0824 Safe Digital Output Field Termination Assembly","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSDO-0824\u003c\/strong\u003e is an 8-channel safe digital output Field Termination Assembly (FTA) engineered for safety control architectures. It acts as an interface between the SICC-0001\/Lx system interconnection cable and field device wiring, routing digital control signals reliably to actuators and final control elements.\u003c\/p\u003e\n\u003ch3\u003eSystem Connectivity and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe assembly interfaces with a redundant pair of SDO-0824 output modules via a dedicated SICC-0001\/Lx system interconnection cable. Across its 8 independent channels, discrete activation commands are distributed directly to external field wiring without compromising redundant signal routing.\u003c\/p\u003e\n\u003ch3\u003eElectrical Ratings and Current Limits\u003c\/h3\u003e\n\u003cp\u003eDesigned in accordance with IEC 61010-1 (IEC 1010) overvoltage category 3, the assembly supports maximum voltages up to 36 V DC. Each channel supports a maximum continuous current of 1.5 A, though the actual operational maximum current is ultimately determined by the connected output module.\u003c\/p\u003e\n\u003ch3\u003eMechanical Design and Terminal Wiring\u003c\/h3\u003e\n\u003cp\u003eThe unit features universal snap-in mounting for standard DIN EN rails (TS32 or TS35 × 7.5 profiles), consuming 61 mm (2.40 in) of rail length. Field connections are made using screw terminals that accommodate wire diameters up to 2.5 mm² (AWG 14), with a required strip length of 7 mm (0.28 in) and a tightening torque of 0.5 Nm (0.37 ft-lb).\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSDO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSafe Digital Output Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e36 V DC (IEC 1010, Overvoltage Category 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Continuous Current per Channel\u003c\/td\u003e\n\u003ctd\u003e1.5 A (defined by connected output module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Cable Interface\u003c\/td\u003e\n\u003ctd\u003eSICC-0001\/Lx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003eRedundant pair of SDO-0824 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN EN TS32 \/ TS35 × 7.5 rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Rail Length\u003c\/td\u003e\n\u003ctd\u003e61 mm (2.40 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Wire Capacity\u003c\/td\u003e\n\u003ctd\u003eMax. 2.5 mm² (AWG 14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Strip Length\u003c\/td\u003e\n\u003ctd\u003e7 mm (0.28 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 Nm (0.37 ft-lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e60 × 70 × 58 mm (2.36 × 2.76 × 2.28 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: How does the FS-TSDO-0824 connect to the main safety output modules?\u003c\/p\u003e\n\u003cp\u003eA: It connects to a redundant pair of SDO-0824 digital output modules using an SICC-0001\/Lx system interconnection cable.\u003c\/p\u003e\n\u003cp\u003eQ: What defines the maximum output current for each channel on the FS-TSDO-0824?\u003c\/p\u003e\n\u003cp\u003eA: While the FTA hardware is rated for up to 1.5 A continuous current per channel at 36 V DC, the actual maximum current limit is governed by the connected output module.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48590045708584,"sku":"FS-TSDO-0824","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/FS-TSDO-0824.png?v=1792399252","url":"https:\/\/www.powerdcs.com\/products\/honeywell-fs-tsdo-0824-safe-digital-output-field-termination-assembly","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}