{"product_id":"honeywell-tc-iah061-96978074-a01-experion-analog-input-module","title":"Honeywell TC-IAH061 96978074-A01 Experion Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-IAH061 96978074-A01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-IAH061\u003c\/strong\u003e Analog Input Modules, operates as a dedicated hardware component for high-speed multi-channel field variable acquisition within Experion PKS C200\/C300 controller chassis platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-IAH061 (Part Number: 96978074-A01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Experion C200\/C300 module enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C housing thermal envelope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.3 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e6 galvanically isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 15 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Update Rate\u003c\/td\u003e\n\u003ctd\u003e25 ms across all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen Circuit Detection\u003c\/td\u003e\n\u003ctd\u003eUpscale reading (Voltage); Zero scale reading (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOC Detection Time\u003c\/td\u003e\n\u003ctd\u003e5 seconds (Voltage); 1 second (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRFI Immunity\u003c\/td\u003e\n\u003ctd\u003eError less than 2.0% of range at 10 V\/m (27 to 1000 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Assembly\u003c\/td\u003e\n\u003ctd\u003eTC-TBNH 20-position terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Loop Protocol Execution\u003c\/h3\u003e\n\u003cp\u003eThe TC-IAH061 module incorporates internal optical barriers providing full channel-to-channel isolation across all 6 analog input channels. Designed to process differential 4-20 mA HART loop protocol and voltage signals, the hardware suppresses common-mode noise and prevents ground loop currents between field devices. Integrated signal-conditioning circuits execute open-circuit detection while maintaining a 25 ms update rate across all channels and filtering RF interference to less than 2.0% error under 10 V\/m field exposure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing a TC-IAH061 module require disconnecting field wiring from the terminal assembly?\u003c\/p\u003e\n\u003cp\u003eA: No, field wiring lands directly on the 20-position TC-TBNH terminal block, allowing the active TC-IAH061 module to be unseated while field conductors stay attached.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TC-IAH061 handle open circuit conditions on current loops versus voltage inputs?\u003c\/p\u003e\n\u003cp\u003eA: Open circuit detection yields a zero-scale reading for current inputs within 1 second, whereas voltage inputs drive to an upscale reading within 5 seconds.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TC-IAH061 module be hot-swapped during active controller operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is supported when installed in compatible backplane racks, subject to site safety rules and cabinet hazardous area classifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSeat the TC-IAH061 module into the designated slot on the chassis rack until the mounting levers snap into the locked position.\u003c\/li\u003e\n\u003cli\u003eAlign the 20-position TC-TBNH terminal block with the module header pins and press firmly to secure mechanical engagement.\u003c\/li\u003e\n\u003cli\u003eTerminate shielded twisted-pair signal cables to the TC-TBNH screw terminals, maintaining proper wire gauge and strip dimensions.\u003c\/li\u003e\n\u003cli\u003eGround all cable drain shields directly to the cabinet enclosure earth ground bar to maintain specified RFI immunity performance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52364666175784,"sku":"TC-IAH061 96978074-A01","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TC-IAH16I_082207fb-4531-4e16-8b20-ee78b7c43c42.png?v=1789028178","url":"https:\/\/www.powerdcs.com\/products\/honeywell-tc-iah061-96978074-a01-experion-analog-input-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}