{"product_id":"invensys-triconex-4000212-002-extension-bus-assembly-kit","title":"Invensys Triconex 4000212-002 Extension Bus Assembly Kit","description":"\u003cp\u003eThe \u003cstrong\u003e4000212-002\u003c\/strong\u003e is an extension bus assembly kit from Invensys Triconex for Trident control architectures. It measures 3.2 cm x 10.7 cm x 13 cm with a 0.3 kg weight, operating from -20 deg C to +70 deg C and meeting ISA S71.04 Class G3 corrosion protection.\u003c\/p\u003e\n\u003ch3\u003eTrident Architecture and Extension Role\u003c\/h3\u003e\n\u003cp\u003eWithin the Trident platform, the \u003cstrong\u003e4000212-002\u003c\/strong\u003e supports extension bus assembly needs in installations using low point counts and distributed I\/O. It helps connect system sections where field signals or I\/O expansion are distributed rather than concentrated in a single local cluster.\u003c\/p\u003e\n\u003cp\u003eCheck your Trident system layout and cable or baseplate arrangement to verify how the extension bus assembly fits the planned chassis or baseplate topology. Always match the exact \u003cstrong\u003e4000212-002\u003c\/strong\u003e ordering number when verifying spares or expansion hardware.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Ratings and Physical Fit\u003c\/h3\u003e\n\u003cp\u003eThe kit is rated for -20 deg C to +70 deg C (-4 deg F to +158 deg F) ambient operating temperature measured at the bottom of the baseplate per IEC 60068-2-14 (tests Na and Nb). Storage is rated from -40 deg C to +85 deg C (-40 deg F to +185 deg F) under IEC 60068-2-2 (test Bb), IEC 60068-2-1 (test Ab), and IEC 60068-2-30 (test Db).\u003c\/p\u003e\n\u003cp\u003eRelative humidity must remain between 5% and 95%, non-condensing, and corrosion resistance meets ISA S71.04 Class G3 based on EIA 364-65A Class III testing. At 3.2 cm x 10.7 cm x 13 cm and 0.3 kg, verify clearance and mechanical mounting provisions in the enclosure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e4000212-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eInvensys Triconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtension Bus Assembly Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Family\u003c\/td\u003e\n\u003ctd\u003eTrident\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrdering Information\u003c\/td\u003e\n\u003ctd\u003e4000212-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.2 cm x 10.7 cm x 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States (US)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C (-4 deg F to +158 deg F) ambient at bottom of baseplate (IEC 60068-2-14, tests Na and Nb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F) (IEC 60068-2-2 test Bb, IEC 60068-2-1 test Ab, IEC 60068-2-30 test Db)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Environment Rating\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 Class G3 (EIA 364-65A Class III)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What operating temperature limits apply to the Invensys Triconex 4000212-002?\u003c\/p\u003e\n\u003cp\u003eA: It is rated for -20 deg C to +70 deg C (-4 deg F to +158 deg F) ambient temperature measured at the bottom of the baseplate per IEC 60068-2-14, tests Na and Nb. Confirm that the air temperature at the baseplate bottom stays within this range during operation.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 4000212-002 suitable for corrosive industrial atmospheres?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it carries an ISA S71.04 Class G3 corrosive environment rating based on EIA 364-65A Class III testing. Relative humidity must also stay within 5% to 95%, non-condensing.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical dimensions and weight of the 4000212-002 kit?\u003c\/p\u003e\n\u003cp\u003eA: The kit measures 3.2 cm x 10.7 cm x 13 cm and weighs 0.3 kg, with origin listed as the United States (US). Verify physical space and mounting clearance in your Trident cabinet before installation.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":68233648767272,"sku":"4000212-002","price":327.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/4000212-002_Cocoai.png?v=1795053364","url":"https:\/\/www.powerdcs.com\/products\/invensys-triconex-4000212-002-extension-bus-assembly-kit","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}