{"product_id":"mc-pha001-51403476-150-honeywell-analog-output-module","title":"MC-PHA001 51403476-150 Honeywell Analog Output Module","description":"\u003cp\u003eConfigured for precise analog signal generation in Honeywell Series 8 and Experion PKS networks, the \u003cstrong\u003eHoneywell 51403476-150\u003c\/strong\u003e (\u003cstrong\u003eMC-PHA001\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PHA001 51403476-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg (Shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via backplane DC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Analog Output Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Range\u003c\/td\u003e\n\u003ctd\u003e0.1–21.4 mA (Directly accessible), Max 26 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Resistive Load\u003c\/td\u003e\n\u003ctd\u003e750 Ohm @ 22 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.35% at 25 deg C (Including linearity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;=100 mV peak-to-peak at power line frequency across 250 Ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Protection\u003c\/td\u003e\n\u003ctd\u003eANSI\/IEEE C37.90.1-1978 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eConformally coated circuit assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe MC-PHA001 module executes continuous control loops by generating analog current signals tailored for final control elements. Designed to integrate directly into 4-20 mA HART loop protocol architectures, the circuit board incorporates channel-to-channel isolation and galvanic protection mechanisms. Redundant topologies feature output isolation via a field-replaceable relay switch on the Field Termination Assembly (FTA), preventing back-feeding and ground loop coupling across redundant control channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is output isolation managed in redundant configurations?\u003c\/p\u003e\n\u003cp\u003eA: Redundant output channels are isolated using a field-replaceable relay switch located on the Field Termination Assembly (FTA) to ensure seamless failure handover without back-feeding current.\u003c\/p\u003e\n\u003cp\u003eQ: What protection measures does the module include against atmospheric contaminants?\u003c\/p\u003e\n\u003cp\u003eA: The printed circuit board features a conformal coating that guards onboard components against humidity, dust, and corrosive industrial chemical gases.\u003c\/p\u003e\n\u003cp\u003eQ: Can the MC-PHA001 output channel drive loads up to 750 Ohm?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is engineered to drive maximum resistive loads up to 750 Ohm at a full 22 mA current output.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the targeted rack slot or verify system redundancy status before inserting the MC-PHA001 module into the Series 8 chassis.\u003c\/li\u003e\n\u003cli\u003eRoute 4-20 mA HART signal lines through twisted-pair shielded cables to prevent electromagnetic coupling from adjacent power wiring.\u003c\/li\u003e\n\u003cli\u003eEnsure the cable shield drain wire is grounded at a single point on the main enclosure grounding bus bar.\u003c\/li\u003e\n\u003cli\u003eVerify all mounting screws on the module and associated FTA connections are seated firmly to maintain chassis grounding and thermal contact.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52393180758312,"sku":"MC-PHA001 51403476-150","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MC-PHA00151403476-150.jpg?v=1789552044","url":"https:\/\/www.powerdcs.com\/products\/mc-pha001-51403476-150-honeywell-analog-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}