{"product_id":"prosoft-mvi46-dfnt-ethernet-ip-client-server-network-interface-module","title":"Prosoft MVI46-DFNT Ethernet\/IP Client\/Server Network Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProsoft MVI46-DFNT Ethernet\/IP Client\/Server Network Interface Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to enhance communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRockwell Automation SLC processors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP networks\u003c\/strong\u003e. This robust solution enables bidirectional command and data exchange, improving operational efficiency and connectivity in industrial automation systems.\u003c\/p\u003e\n\u003cp\u003eThis module supports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 servers\u003c\/strong\u003e, allowing multiple connections and seamless data transfer within complex environments. Its compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-slot design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures ease of integration, making it an ideal choice for various industrial applications where space and efficiency are crucial.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e: Supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor robust and reliable connectivity with networked devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Servers\u003c\/strong\u003e: Can handle up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 servers\u003c\/strong\u003e, ensuring effective communication across multiple devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommand Support\u003c\/strong\u003e: Capable of executing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eread and write commands\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor precise control of network devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSingle-slot solution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy integration with existing systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Area\u003c\/strong\u003e: Ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring reliable network communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMVI46-DFNT Ethernet\/IP Client\/Server Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(DF1 for Ethernet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Servers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20 servers\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommand Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eRead and Write\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLow power usage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-10°C to 55°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5% to 95% RH, non-condensing\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSingle-slot design\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eLightweight for easy installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications \u0026amp; Functions\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProsoft MVI46-DFNT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is engineered to enhance the performance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRockwell Automation SLC processors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby enabling seamless communication between remote devices over\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003enetworks. It supports bidirectional data flow, allowing users to send and receive commands, which is essential for real-time monitoring and control applications.\u003c\/p\u003e\n\u003cp\u003eThis module is perfect for applications in various industries, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Automation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the main functionality of the\u003cspan\u003e \u003c\/span\u003eMVI46-DFNT\u003cspan\u003e \u003c\/span\u003emodule?\u003c\/strong\u003e\u003cbr\u003eA1: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI46-DFNT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule facilitates communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRockwell Automation SLC processors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEtherNet\/IP networks\u003c\/strong\u003e, enabling bidirectional command and data exchange.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many servers can the\u003cspan\u003e \u003c\/span\u003eMVI46-DFNT\u003cspan\u003e \u003c\/span\u003emodule support?\u003c\/strong\u003e\u003cbr\u003eA2: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI46-DFNT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 servers\u003c\/strong\u003e, making it suitable for large-scale industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What types of commands can the\u003cspan\u003e \u003c\/span\u003eMVI46-DFNT\u003cspan\u003e \u003c\/span\u003emodule execute?\u003c\/strong\u003e\u003cbr\u003eA3: The module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eread and write commands\u003c\/strong\u003e, ensuring precise control over networked devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is the operating temperature range of the\u003cspan\u003e \u003c\/span\u003eMVI46-DFNT?\u003c\/strong\u003e\u003cbr\u003eA4: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI46-DFNT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates in temperatures ranging from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-10°C to 55°C\u003c\/strong\u003e, with a wide humidity tolerance of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5% to 95% RH\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: How does the\u003cspan\u003e \u003c\/span\u003eMVI46-DFNT\u003cspan\u003e \u003c\/span\u003eintegrate into existing systems?\u003c\/strong\u003e\u003cbr\u003eA5: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI46-DFNT\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-slot design\u003c\/strong\u003e, making it easy to install into existing systems without requiring significant space or reconfiguration.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":50826795745576,"sku":"MVI46-DFNT","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/MVI46-DFNT1.jpg?v=1760342552","url":"https:\/\/www.powerdcs.com\/products\/prosoft-mvi46-dfnt-ethernet-ip-client-server-network-interface-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}