{"product_id":"prosoft-plx31-mbtcp-mbs4-modbus-tcp-ip-to-modbus-gateway","title":"Prosoft PLX31-MBTCP-MBS4 Modbus TCP\/IP to Modbus Gateway","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProsoft PLX31-MBTCP-MBS4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egateway is a powerful communication interface designed to bridge\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP networks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\/ASCII\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edevices. Built for high-performance industrial automation systems, it ensures fast, reliable data transfer between control equipment, PLCs, and field devices.\u003c\/p\u003e\n\u003cp\u003eThis gateway provides flexible connectivity options, supporting both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus Master and Slave\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodes. It enables seamless communication across different network architectures, optimizing data management and control efficiency in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConverts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP\/IP to Modbus RTU\/ASCII\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eefficiently.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 Modbus TCP clients\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 Modbus servers\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e160 configurable client commands\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith adjustable polling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS232, RS422, and RS485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterfaces for multi-device compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e255-byte transmit buffer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith customizable character delays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides individual error codes and status tracking for each Modbus command.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePLX31-MBTCP-MBS4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eProsoft Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP to Modbus Master\/Slave Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Clients\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Servers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMBAP 5, Encapsulated 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommand Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 160 configurable client commands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePolling Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous or on data change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Reporting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndividual error codes and slave status list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNode Address Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–247 (software selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRS Interface Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS232, RS422, RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmit\/Receive Buffer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255-byte transmit character length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacter Delay Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–65535 ms adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus Master \/ Modbus Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProsoft Configuration Builder (PCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C (-13°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade compact design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Are all Prosoft PLX31-MBTCP-MBS4 gateways brand new?\u003c\/strong\u003e\u003cbr\u003eYes, all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLX31-MBTCP-MBS4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits are 100% new, original, and factory-sealed from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProsoft Technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the typical shipping time for this model?\u003c\/strong\u003e\u003cbr\u003eWe usually ship within\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3 days to 2 weeks\u003c\/strong\u003e, depending on the order size and shipping method (DHL, FedEx, or UPS).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the PLX31-MBTCP-MBS4 operate in harsh environments?\u003c\/strong\u003e\u003cbr\u003eYes, it performs reliably within a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature range of -25°C to 70°C\u003c\/strong\u003e, making it suitable for industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How many Modbus devices can it handle simultaneously?\u003c\/strong\u003e\u003cbr\u003eIt supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 Modbus TCP clients\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 Modbus servers\u003c\/strong\u003e, and up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e160 configurable commands\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor maximum flexibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: What if there is a quality issue after purchase?\u003c\/strong\u003e\u003cbr\u003eWe provide a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30-day return policy\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor any verified quality-related issues.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":50828954403112,"sku":"PLX31-MBTCP-MBS4","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/PLX31-MBTCP-MBS41.jpg?v=1760423361","url":"https:\/\/www.powerdcs.com\/products\/prosoft-plx31-mbtcp-mbs4-modbus-tcp-ip-to-modbus-gateway","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}