{"product_id":"tc-kccx03-experion-pks-digital-controller-honeywell","title":"TC-KCCX03 Experion PKS Digital Controller | Honeywell","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell TC-KCCX03\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTC-KCCX03\u003c\/strong\u003e CPU Processors, operates as a dedicated hardware component for high-speed logic execution and real-time data communication within Honeywell Experion PKS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-KCCX03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.17 kg (13.60 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C200\/C300 Chassis Slot Occupancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane System Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Category\u003c\/td\u003e\n\u003ctd\u003eDigital Process Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System (DCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMount Configuration\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell C200\/C300 Controller Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eIntegrated backplane bus for high-speed data exchange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eCPU Processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Connectivity \u0026amp; 4-20 mA HART Loop Integration\u003c\/h3\u003e\n\u003cp\u003eThe TC-KCCX03 digital controller coordinates high-density point counts and PID control loops across connected chassis racks. Built-in backplane communication protocols enable data interchange with field gateway modules, supporting both 4-20 mA HART loop protocol devices and FOUNDATION Fieldbus \/ Profibus PA connectivity networks. Internal galvanic isolation paths isolate central logic execution circuits from field side electrical interference, preventing ground loop current propagation and maintaining signal fidelity under continuous process operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the TC-KCCX03 controller compatible with both Series A and Series C I\/O assemblies?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility with specific I\/O series depends on the controller firmware version and the installed chassis bridge modules.\u003c\/p\u003e\n\u003cp\u003eQ: How is memory retention maintained on the TC-KCCX03 during a main rack power outage?\u003c\/p\u003e\n\u003cp\u003eA: Non-volatile storage holds the system configuration, while an optional backup battery assembly (such as the TC-BATT01) maintains real-time clock and volatile RAM parameters during scheduled power cycles.\u003c\/p\u003e\n\u003cp\u003eQ: Can the TC-KCCX03 module be removed under power during live chassis maintenance?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted to redundant controller configurations; single-controller racks require system shutdown or transfer to a redundant secondary processor prior to removal.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSlide the TC-KCCX03 module vertically into the designated controller chassis slot until top and bottom retention latches engage firmly.\u003c\/li\u003e\n\u003cli\u003eTighten all panel retention screws to secure the 6.17 kg module assembly against chassis vibration.\u003c\/li\u003e\n\u003cli\u003eConnect dedicated cabinet grounding jumpers from the chassis frame directly to the main earth ground bar before applying system power.\u003c\/li\u003e\n\u003cli\u003eVerify forced-air ventilation or cabinet fan assemblies are fully operational to maintain ambient thermal conditions within specified operational limits.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52364736430376,"sku":"TC-KCCX03","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/TC-IDJ1612_Cocoai_7eb0d319-5b23-4ff8-b941-bb53197a0972.png?v=1789029965","url":"https:\/\/www.powerdcs.com\/products\/tc-kccx03-experion-pks-digital-controller-honeywell","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}