{"product_id":"triconex-3636t-digital-relay-output-module","title":"Triconex 3636T Digital Relay Output Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriconex 3636T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity digital relay output module engineered for Triconex safety systems. It delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 individually isolated relay outputs\u003c\/strong\u003e, ideal for controlling alarms, solenoids, and shutdown valves.\u003c\/p\u003e\n\u003cp\u003eDesigned for fault-tolerant architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3636T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports hot-replacement, redundant configurations, and advanced diagnostics. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3 certification\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures compliance with safety instrumented system standards, maximizing operational reliability in critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e32 Individually Isolated Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel provides electrical isolation for reliable actuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSIL 3 Certified:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompliant with IEC 61508, suitable for safety-critical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectromechanical Relay Outputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles AC or DC loads with dry contact switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects relay coil or contact failures per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swappable Module:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReplacement during operation without process interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully compatible with Tricon fault-tolerant systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Control Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports diverse industrial control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e490 × 453 × 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay (Form A – normally open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2 A @ 30 VDC \/ 0.5 A @ 125 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V channel-to-channel \u0026amp; system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Voltage\u003c\/td\u003e\n\u003ctd\u003eUp to 125 VAC or 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eElectromechanical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eEnvironmental Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2 compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eTriconex Tricon Safety Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Relay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508), TÜV Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Instrumented Systems (SIS):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures reliable relay outputs in critical safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControls alarms, solenoids, and process shutdown devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWorks in redundant Triconex configurations to maintain uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQs\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the Triconex 3636T brand new?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3636T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis 100% original, brand new, and in stock.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many relay output channels does it support?\u003c\/strong\u003e\u003cbr\u003eIt provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 individually isolated channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor diverse industrial applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What certifications does the module have?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3636T\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL 3 certified\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eaccording to IEC 61508 and TÜV tested.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can it be replaced while the system is running?\u003c\/strong\u003e\u003cbr\u003eYes, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e, allowing replacement without process interruption.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":50829261504808,"sku":"3636T","price":369.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/6266\/2184\/files\/3636T1.jpg?v=1760425554","url":"https:\/\/www.powerdcs.com\/products\/triconex-3636t-digital-relay-output-module","provider":"Power DCS Parts Limited","version":"1.0","type":"link"}